Storage Tank Accessory2018. 8. 29. 14:08

DESIGN AND FUNCTION

Model FA21, FA23 is bi-directional type and designed to be installed in “open vent pipes” from storage or processing tanks, bleed lines or other vapor conveying lines.
The flame arrester consists of a spiral wound and crimped bank element, is designed for easy maintenance.
After removing tie rod bolts, it can be expanded by using the remaining jackscrews for element exchange.

Model FA21T, FA23T is used to prevent propagation of an external flame source through the vent opening and into the tank. It should be installed at distances of more than 20 times length of arrester N.D away from the open end of pipe.

 

 

SPECIFICATIONS

 Installation

 Vertical, recommend
Required drain plug for horizontal installation

 Type

 In-line flame arrester

 Size

 1",2",3",4",6",8",10",12",14",16"

 Classification

 Deflagration flame arrester, Bi-directional

 Normal working pressure

 Below 1.0 barg(standard speciafication)

 Explosion gas group

 IIA(standard), IIB/IIC(for special application)

 

MATERIALS

 PART NAME

 MATERIALS STANDARD

 MATERIALS OPTIONAL

 Body

 Carbon Steel, 304 S.S, 316 S.S,Aluminum

 Hastelloy, Alloy 20, Monel, Inconel

 Flame Element

 316L S.S

Hastelloy, Alloy 20, Monel, Inconel 

 Element Housing

 304 S.S, 316 S.S 316L S.S

 Hastelloy, Alloy 20, Monel, Inconel

 Stud Bolt and Nut

 C.S, 304 S.S 316 S.S

 316 S.S

 

INSPECTION AND INSTALLATION

All NEOTECHKOREA flame arresters are bi-directional and the installation on a tank or piping system depends to a great extent on the design of the system. The Model NK-FA21T is recommended for vertical installation in closed piping systems or venting to atmosphere. (Model NK-FA23T:
Horizontal Installation) If a Model NK-FA21T is installed in a horizontal line, it should be equipped with drain ports for removal of condensation from the housing.

 

DRAWING AND DIMENSION (NK-FA21T)  Unit : (mm)


 

 

 SIZE

2" 

3" 

4" 

6" 

8" 

10" 

12" 

I.D

50 

 80

 100

 150

 200

 250

 300

 H

 280

 290

 355

 358

 397

 463

 520

 L

 225

 263

 310

 400

 479

 575

 663

 

 

FLOW CAPACITY

• Storage Tank Accessory
• Tel : 82 55 762 0019 Fax : 82 55 762-2251
• Email:neotech@neotechkorea.com
• Name : KyungRo Lee

• Homepage : http://www.corpwin.com

'Storage Tank Accessory' 카테고리의 다른 글

Deflagration Flame Arrester (NK-FA23T)  (0) 2018.08.30
Deflagration Flame Arrester (NK-FA22T)  (0) 2018.08.30
Detonation Flame arrester  (0) 2018.08.29
Flame arrester  (0) 2018.08.29
Breather Valve with Flame arrester (NK-BVF70 Series)  (0) 2018.08.28
Posted by 노가다팀장